WEBVTT

1
00:00:03.410 --> 00:00:08.650
Kasana changing the way the world clean

2
00:00:14.000 --> 00:00:19.380
welcome and thank you for purchasing the

3
00:00:16.410 --> 00:00:21.390
Lotus Pro high-capacity unit before we

4
00:00:19.380 --> 00:00:24.240
begin installing the unit here are a few

5
00:00:21.390 --> 00:00:26.580
quick notes always install the Lotus Pro

6
00:00:24.240 --> 00:00:29.160
high-capacity unit indoors in a dry

7
00:00:26.580 --> 00:00:31.439
location the unit must always be

8
00:00:29.160 --> 00:00:34.530
installed vertically never horizontally

9
00:00:31.439 --> 00:00:37.170
or at any angle the high capacity unit

10
00:00:34.530 --> 00:00:38.790
and stabilization module must be level

11
00:00:37.170 --> 00:00:41.100
and flush against the wall with the

12
00:00:38.790 --> 00:00:43.649
bottom no less than 48 inches from the

13
00:00:41.100 --> 00:00:46.589
floor not doing so will damage the unit

14
00:00:43.649 --> 00:00:48.390
the unit and stabilizer should always be

15
00:00:46.589 --> 00:00:50.780
installed directly above a sink or a

16
00:00:48.390 --> 00:00:50.780
drain

17
00:00:59.850 --> 00:01:03.940
carefully remove all the items from the

18
00:01:02.199 --> 00:01:06.430
cartons and remove mounting hardware

19
00:01:03.940 --> 00:01:09.190
from plastic packages please note that

20
00:01:06.430 --> 00:01:11.369
the unit ships with extra MSDS stickers

21
00:01:09.190 --> 00:01:14.020
please put these aside for future use

22
00:01:11.369 --> 00:01:17.360
place the mounting template on the wall

23
00:01:14.020 --> 00:01:19.720
in desired location while using a level

24
00:01:17.360 --> 00:01:22.430
tape down the corners to hold in place

25
00:01:19.720 --> 00:01:25.160
double check to ensure stabilizer and

26
00:01:22.430 --> 00:01:26.990
drain line on HC you are located

27
00:01:25.160 --> 00:01:29.330
directly above a sink or drain

28
00:01:26.990 --> 00:01:31.190
note that the template can be used in

29
00:01:29.330 --> 00:01:33.140
Reverse if it works out better to have

30
00:01:31.190 --> 00:01:36.320
the stabilization module on the right

31
00:01:33.140 --> 00:01:38.450
side of the unit using a 3/8 drill bit

32
00:01:36.320 --> 00:01:41.180
make four holes for the high capacity

33
00:01:38.450 --> 00:01:43.610
unit recommend using slotted openings on

34
00:01:41.180 --> 00:01:45.470
bottom of template and then using a

35
00:01:43.610 --> 00:01:47.990
quarter drill bit make four for the

36
00:01:45.470 --> 00:01:50.240
stabilization unit bracket use a hammer

37
00:01:47.990 --> 00:01:53.600
and place blue plastic anchors that are

38
00:01:50.240 --> 00:01:56.960
provided into the holes starting with

39
00:01:53.600 --> 00:01:59.150
the hcu use the 3/8 screws and insert

40
00:01:56.960 --> 00:02:01.850
the bottom screws into the anchors for

41
00:01:59.150 --> 00:02:04.250
the slotted openings first drive them in

42
00:02:01.850 --> 00:02:06.920
only partway and then use these as

43
00:02:04.250 --> 00:02:09.200
support to hold the hcu in place while

44
00:02:06.920 --> 00:02:11.840
you insert the top two screws don't

45
00:02:09.200 --> 00:02:13.730
forget to tighten the lower screws the

46
00:02:11.840 --> 00:02:15.770
drain lines should be attached to the

47
00:02:13.730 --> 00:02:19.430
wall and can be cut shorter if needed

48
00:02:15.770 --> 00:02:21.830
but no shorter than 16 inches attach

49
00:02:19.430 --> 00:02:24.200
stabilizer bracket to wall using inch

50
00:02:21.830 --> 00:02:26.420
and a quarter screws once bracket is

51
00:02:24.200 --> 00:02:29.360
mounted hang the stabilization module

52
00:02:26.420 --> 00:02:31.910
the new hose sets supplied with the unit

53
00:02:29.360 --> 00:02:34.300
are to be used old hose sets should not

54
00:02:31.910 --> 00:02:36.580
be reused

55
00:02:34.300 --> 00:02:38.950
use the hose with blue red connector

56
00:02:36.580 --> 00:02:40.600
line up and attach to blue connector

57
00:02:38.950 --> 00:02:43.060
outlet on the left side of the

58
00:02:40.600 --> 00:02:45.550
stabilization unit connect the other end

59
00:02:43.060 --> 00:02:47.890
to the cold water supply using a Y

60
00:02:45.550 --> 00:02:50.920
connector so that client can attach a

61
00:02:47.890 --> 00:02:53.590
hose to get tap water if needed if

62
00:02:50.920 --> 00:02:55.900
possible it is beneficial to connect to

63
00:02:53.590 --> 00:02:58.240
a dedicated cold water supply so that

64
00:02:55.900 --> 00:03:01.330
hot water cannot be used with unit if

65
00:02:58.240 --> 00:03:03.280
this is not possible then inquire if hot

66
00:03:01.330 --> 00:03:05.590
water handle can be removed to ensure

67
00:03:03.280 --> 00:03:08.260
only cold water is used with the high

68
00:03:05.590 --> 00:03:10.540
capacity unit attach black white

69
00:03:08.260 --> 00:03:13.480
connector hose supplied to right side

70
00:03:10.540 --> 00:03:16.270
outlet on stabilization module attach

71
00:03:13.480 --> 00:03:18.940
opposite end to cold water in on high

72
00:03:16.270 --> 00:03:21.090
capacity unit make sure the hose is

73
00:03:18.940 --> 00:03:24.580
flush to the unit and tighten the clamp

74
00:03:21.090 --> 00:03:27.100
attach hose with yellow handle to ozone

75
00:03:24.580 --> 00:03:29.850
solution outs on high capacity unit

76
00:03:27.100 --> 00:03:33.130
barbed fitting clamp is not required

77
00:03:29.850 --> 00:03:35.940
connect power cord only to a 110 volt

78
00:03:33.130 --> 00:03:38.890
power outlet and clip neatly to wall if

79
00:03:35.940 --> 00:03:41.080
outlet is more than 10 feet away further

80
00:03:38.890 --> 00:03:43.660
than supplied power cord then please

81
00:03:41.080 --> 00:03:47.760
call to have appropriate cord sent it is

82
00:03:43.660 --> 00:03:47.760
not advisable to use an extension cord

83
00:03:56.190 --> 00:04:01.110
peel backing off two-way tape on back of

84
00:03:59.100 --> 00:04:03.720
use and care guide and place on wall

85
00:04:01.110 --> 00:04:05.670
next to unit now that you have

86
00:04:03.720 --> 00:04:07.950
successfully installed the Lotus Pro

87
00:04:05.670 --> 00:04:09.450
high-capacity unit we will go through

88
00:04:07.950 --> 00:04:12.360
the steps of starting it up for the

89
00:04:09.450 --> 00:04:14.490
first time unwrap the blue cartridge and

90
00:04:12.360 --> 00:04:17.730
place him unit ensuring it is properly

91
00:04:14.490 --> 00:04:20.100
in you will hear a click and sure cold

92
00:04:17.730 --> 00:04:22.530
water in hose is attached to open faucet

93
00:04:20.100 --> 00:04:27.510
or permanent cold water source with a

94
00:04:22.530 --> 00:04:33.090
minimum of 30 psi 207 kPa at a maximum

95
00:04:27.510 --> 00:04:36.450
65 psi 488 kPa using a Y connector then

96
00:04:33.090 --> 00:04:39.630
turn the water on to start press flow

97
00:04:36.450 --> 00:04:42.300
switch to on position when system ready

98
00:04:39.630 --> 00:04:45.030
indicator is green dispensed in to mop

99
00:04:42.300 --> 00:04:47.930
bucket auto scrubber carpet extractor or

100
00:04:45.030 --> 00:04:47.930
spray bottle

101
00:04:54.410 --> 00:04:59.789
shut unit off when not in use by

102
00:04:57.419 --> 00:05:02.550
pressing flow switch to off position and

103
00:04:59.789 --> 00:05:05.310
turn the water off if the change

104
00:05:02.550 --> 00:05:07.229
stabilizer yellow light turns on check

105
00:05:05.310 --> 00:05:09.720
to make sure the blue filter is fully

106
00:05:07.229 --> 00:05:11.669
inserted and you have heard a click if

107
00:05:09.720 --> 00:05:13.680
you turn on the unit and water does not

108
00:05:11.669 --> 00:05:15.569
dispense then make sure the quick

109
00:05:13.680 --> 00:05:18.389
disconnects are connected tightly to the

110
00:05:15.569 --> 00:05:21.720
stabilization module thank you and enjoy

111
00:05:18.389 --> 00:05:24.840
cleaning sanitizing and deodorizing with

112
00:05:21.720 --> 00:05:26.310
terzano stabilized aqueous ozone if you

113
00:05:24.840 --> 00:05:28.620
are having any issues during

114
00:05:26.310 --> 00:05:30.990
installation please feel free to call

115
00:05:28.620 --> 00:05:33.479
our toll-free service line one eight

116
00:05:30.990 --> 00:05:36.110
hundred seven two seven eight eight

117
00:05:33.479 --> 00:05:36.110
three five

118
00:05:41.610 --> 00:05:44.119
[Music]